7462 results for Electric Motors

Electric Motors

7381 - 7400 of 7462

Key Features


  • Meets or exceeds NEMA Premium® efficiencies
  • Meets IEEE-841 standard for severe duty motor applications
  • MAX GUARD® Class F insulation system
  • Capable of Constant Torque speed range (as noted in catalog)
  • 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power
  • Meets IEEE45 USCG marine duty, API RP14F for offshore platforms, IP56
  • Meets General Motors® GM® 7E-TA automotive duty specification
  • Inpro/Seal® VBX® bearing isolators on drive end shaft extension TENV and on both ends of TEFC
  • Provisions to add stub shaft for an encoder (182T-449T, TEFC only)

Key Features


  • Meets or exceeds NEMA Premium® efficiencies, except where noted NEMA Premium® models are in compliance with EISA2007
  • Suitable for use on a VFD. Variable Torque and Constant Torque (as noted)
  • 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power
  • F1 conduit box on Rigid Base, F3 on C-Face Footed (Rigid Base) motors
  • Bearing Current Protection (BCP), as noted
  • Shaft slinger, Class F insulation, 1.15 Service Factor, Ball bearings (except as noted
  • C-Face Footed models are rated 60/50 Hz, same HP
  • Motors accept C-face kits, as noted
  • UL Recognized, CSA Certified and CE Mark

Key Features


  • Meets or exceeds NEMA Premium® efficiency. Model is in compliance with EISA2007
  • Meets IEEE-841 standard for severe duty applications
  • Constant Torque speed range is listed in CT SPEED RANGE column
  • Blue Chip® quality, 100% cast iron construction for rigidity and reduced vibration
  • Inpro/Seal® VBX® bearing isolators on drive end shaft extension TENV and on both ends of TEFC
  • Provisions to add stub shaft for an encoder (182T-449T, TEFC only)
  • Internal and external epoxy finish
  • MAX GUARD® Class F insulation system

Fire Pump Motor, 250 HP, 3 Ph, 60 Hz, 575 V, 3600 RPM, 445TS Frame, DP

Part #:445TSTDCD4008
Catalog #:U1130
Sorry, this item is no longer available

Key Features


  • Designed for use on pumps for fire pump duty
  • UL file EX5190, CSA file LR2025 and CE mark
  • 50°C ambient
  • Red paint on 25 HP through 200 HP
  • NEMA Design B, Code G or less
  • Single voltage motors have 12 leads and are suitable for wye-delta, across the line, or part winding start
  • Dual voltage motors have 12 leads, suitable for wye-delta or across the line start on either voltage, or part winding start on low voltage

Key Features


  • Suitable for use on a VFD. Variable Torque and Constant Torque (as noted)
  • 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power
  • F1 conduit box on Rigid Base, F3 on C-Face Footed (Rigid Base) motors
  • Bearing Current Protection (BCP), as noted
  • Shaft slinger, Class F insulation
  • Ball bearings (except as noted )
  • C-Face Footed models are rated 60/50 Hz, same HP
  • Motors accept C-face kits, as noted
  • UL Recognized, CSA Certified and CE Mark
Fire Pump Motor, 250 HP, 3 Ph, 50 Hz, 415 V, 3000 RPM, 445TS Frame, DP

Fire Pump Motor, 250 HP, 3 Ph, 50 Hz, 415 V, 3000 RPM, 445TS Frame, DP

Part #:445TSTDCD4005
Catalog #:U1439
Sorry, this item is no longer available

Key Features


  • IP-22 cast iron, Meets or exceeds NEMA Premium®* efficiencies, NEMA Premium models are in compliance with EISA2007
  • Class F Insulation System, NEMA® design B, code G or less
  • Dual voltage motors have 12 leads, suitable for wye-delta or across the line start on either voltage, or part winding start on low voltage
  • Single voltage motors have 12 leads and are suitable for wye-delta, across the line, or part winding start
  • Red paint, Bearing Caps both ends, Grease Fittings with pipe plugs, Modifications and Kits are available
  • 50°C Ambient, 1.15SF Sine Wave Power Only
  • UL file EX5190, CSA file LR2025 and CE mark
Fire Pump Motor, 250 HP, 3 Ph, 50 Hz, 415 V, 1500 RPM, 445TS Frame, DP

Fire Pump Motor, 250 HP, 3 Ph, 50 Hz, 415 V, 1500 RPM, 445TS Frame, DP

Part #:445TSTDCD4029
Catalog #:U1440
Sorry, this item is no longer available

Key Features


  • IP-22 cast iron, Meets or exceeds NEMA Premium®* efficiencies, NEMA Premium models are in compliance with EISA2007
  • Class F Insulation System, NEMA® design B, code G or less
  • Dual voltage motors have 12 leads, suitable for wye-delta or across the line start on either voltage, or part winding start on low voltage
  • Single voltage motors have 12 leads and are suitable for wye-delta, across the line, or part winding start
  • Red paint, Bearing Caps both ends, Grease Fittings with pipe plugs, Modifications and Kits are available
  • 50°C Ambient, 1.15SF Sine Wave Power Only
  • UL file EX5190, CSA file LR2025 and CE mark

Fire Pump Motor, 250 HP, 3 Ph, 60 Hz, 575 V, 1800 RPM, 447TS Frame, DP

Part #:445TSTDCD4036
Catalog #:U1131
Sorry, this item is no longer available

Key Features


  • Designed for use on pumps for fire pump duty
  • UL file EX5190, CSA file LR2025 and CE mark
  • 50°C ambient
  • Red paint on 25 HP through 200 HP
  • NEMA Design B, Code G or less
  • Single voltage motors have 12 leads and are suitable for wye-delta, across the line, or part winding start
  • Dual voltage motors have 12 leads, suitable for wye-delta or across the line start on either voltage, or part winding start on low voltage

Key Features


  • Meets or exceeds NEMA Premium® efficiency. Model is in compliance with EISA2007
  • Rated 60/50 hertz, 190/380 volt at next lower horsepower
  • 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power
  • F1 conduit box on Rigid Base, F3 on C-Face Footed (Rigid Base) motors
  • Motor will accept a C-face kit
  • Shaft slinger, Class F insulation
Fire Pump Motor, 200 HP, 3 Ph, 50 Hz, 415 V, 1500 RPM, 445TS Frame, DP

Fire Pump Motor, 200 HP, 3 Ph, 50 Hz, 415 V, 1500 RPM, 445TS Frame, DP

Part #:445TSTDCD4028
Catalog #:U1437
Sorry, this item is no longer available

Key Features


  • IP-22 cast iron, Meets or exceeds NEMA Premium®* efficiencies, NEMA Premium models are in compliance with EISA2007
  • Class F Insulation System, NEMA® design B, code G or less
  • Dual voltage motors have 12 leads, suitable for wye-delta or across the line start on either voltage, or part winding start on low voltage
  • Single voltage motors have 12 leads and are suitable for wye-delta, across the line, or part winding start
  • Red paint, Bearing Caps both ends, Grease Fittings with pipe plugs, Modifications and Kits are available
  • 50°C Ambient, 1.15SF Sine Wave Power Only
  • UL file EX5190, CSA file LR2025 and CE mark

Key Features


  • Meets or exceeds NEMA Premium® efficiency. Model is in compliance with EISA2007
  • C-Face Footed models are rated 60/50 Hz, same HP
  • 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power
  • F1 conduit box on Rigid Base, F3 on C-Face Footed (Rigid Base) motors
  • Motor will accept a C-face kit
  • Shaft slinger, Class H insulation

Key Features


  • Designed for use on pumps for fire pump duty
  • UL file EX5190, CSA file LR2025 and CE mark
  • 50°C ambient
  • NEMA Design B, Code G or less
  • Single voltage motors have 12 leads and are suitable for wye-delta, across the line, or part winding start
  • Red paint

Key Features


  • IP22, NEMA® EPACT Efficiency, Fire Pump motors are not recommended for use with variable frequency drives.
  • NEMA® design B, code G or less
  • Dual voltage motors have 12 leads, suitable for wye-delta or across the line start on either voltage, or part winding start on low voltage
  • Single voltage motors have 12 leads and are suitable for wye-delta, across the line, or part winding start
  • Class F Insulation, 50C Max Ambient, 1.15 service factor (except as noted)
  • Red paint
  • Ball bearings
  • Will accept C-Face kits (except as noted), see accessories section for kits
  • UL file EX5190, CSA file LR2025 and CE mark

Fire Pump Motor, 200 HP, 3 Ph, 60 Hz, 575 V, 1800 RPM, 445TS Frame, DP

Part #:445TSTDCD4035
Catalog #:U1128
Sorry, this item is no longer available

Key Features


  • Designed for use on pumps for fire pump duty
  • UL file EX5190, CSA file LR2025 and CE mark
  • 50°C ambient
  • Red paint on 25 HP through 200 HP
  • NEMA Design B, Code G or less
  • Will accept C-Face kits.
  • Single voltage motors have 12 leads and are suitable for wye-delta, across the line, or part winding start
  • Dual voltage motors have 12 leads, suitable for wye-delta or across the line start on either voltage, or part winding start on low voltage

Key Features


  • Blue Chip® quality, 100% cast iron construction for rigidity and reduced vibration
  • NEMA Design C 4140 Shaft Material
  • Roller Bearing on Drive End for belted loads
  • 80° C rise at rated load
  • Class F insulation
  • Inpro® Smart Ring, rotating shaft seals on each end of shaft
  • Internal and external epoxy finish
  • Brass drain and breather
  • 12 Leads for WYE-DELTA, part winding on low voltage, or across-the-line starting
  • Will become build-up item when current stock is gone

Key Features


  • Meets or exceeds NEMA Premium® efficiency. Model is in compliance with EISA2007
  • Meets IEEE45 USCG Marine Duty, IP54 Construction, Meets Ford EM1 Automotive Duty Specification
  • Blue Chip® quality, 100% cast iron construction for rigidity and reduced vibration
  • Provisions to add stub shaft for an encoder (182T-449T, TEFC only)
  • Internal and external epoxy paint
  • MAX GUARD® Class H insulation system
  • Constant Torque speed range is listed in CT SPEED RANGE column
  • 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power
  • Bearing caps (254T and larger), Precision balanced to .08”/sec

Key Features


  • Meets or exceeds NEMA Premium® efficiencies, except where noted NEMA Premium® models are in compliance with EISA2007
  • Suitable for use on a VFD. Variable Torque and Constant Torque (as noted)
  • 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power
  • F1 conduit box on Rigid Base, F3 on C-Face Footed (Rigid Base) motors
  • Bearing Current Protection (BCP), as noted
  • Shaft slinger, Class F insulation, 1.15 Service Factor, Ball bearings (except as noted
  • C-Face Footed models are rated 60/50 Hz, same HP
  • Motors accept C-face kits, as noted
  • UL Recognized, CSA Certified and CE Mark

Key Features


  • Meets or exceeds NEMA Premium® efficiency. Model is in compliance with EISA2007
  • Meets IEEE45 USCG Marine Duty, IP54 Construction, Meets Ford EM1 Automotive Duty Specification
  • Blue Chip® quality, 100% cast iron construction for rigidity and reduced vibration
  • Provisions to add stub shaft for an encoder (182T-449T, TEFC only)
  • Internal and external epoxy paint
  • MAX GUARD® Class H insulation system
  • Constant Torque speed range is listed in CT SPEED RANGE column
  • 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power
  • Bearing caps (254T and larger), Precision balanced to .08”/sec

Key Features


  • Meets or exceeds NEMA Premium® efficiency. Model is in compliance with EISA2007
  • Motor will accept a C-face kit
  • 12 Leads for WYE-DELTA, part winding on low voltage, or across-the-line starting
  • Rated 60/50 hertz, 190/380 or 380 volt at next lower horsepower
  • Class H insulation

Key Features


  • Meets or exceeds NEMA Premium® efficiencies, except where noted NEMA Premium® models are in compliance with EISA2007
  • Suitable for use on a VFD. Variable Torque and Constant Torque (as noted)
  • 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power
  • F1 conduit box on Rigid Base, F3 on C-Face Footed (Rigid Base) motors
  • Bearing Current Protection (BCP), as noted
  • Shaft slinger, Class F insulation, 1.15 Service Factor, Ball bearings (except as noted
  • C-Face Footed models are rated 60/50 Hz, same HP
  • Motors accept C-face kits, as noted
  • UL Recognized, CSA Certified and CE Mark