Key Features


  • Blue Chip® quality, 100% cast iron construction for rigidity and reduced vibration
  • NEMA Design C 4140 Shaft Material
  • Roller Bearing on Drive End for belted loads
  • 80C rise at rated load
  • Class F insulation
  • Inpro® Smart Ring, rotating shaft seals on each end of shaft
  • Internal and external epoxy finish
  • Brass drain and breather
  • Actual test and vibration data supplied with each motor
  • 12 Leads for WYE-DELTA, part winding on low voltage, or across-the-line starting

Check Inventory


Key Features


  • Meets or exceeds NEMA Premium® efficiency. Model is in compliance with EISA2007
  • IP55 enclosure on cast iron frames
  • Inverter Duty 10:1 Variable Torque and 10:1 Constant Torque
  • Class F Insulation 40C Max Ambient, 1.0SF on Inveter Power and 1.15SF on Sine Wave Power
  • Standard F1, reversible to F2 assembly. Dual frame mounting holes.
  • C-face addition may result in non-NEMA "BA" dim. For new "BA" dim consult chart found in modification section
  • Hazardous Duty Division 2, Zone 2, Class I, Groups A,B,C,D, Temperature code T2B
  • UL® Recognized & CSA certified and CE® Mark

Check Inventory


Key Features


  • Meets or exceeds NEMA Premium® efficiencies
  • Hazardous Duty Division 2, Zone 2, Class I, Groups A,B,C,D, Temperature code T2B
  • IP55 enclosure
  • Inverter Duty 10:1 Variable Torque and up to 10:1 Constant Torque
  • Class F Insulation
  • Standard F1, reversible to F2 assembly
  • Dual frame mounting holes

Check Inventory


Key Features


  • No features available

Check Inventory


Key Features


  • Meets or exceeds NEMA Premium® efficiency. Model is in compliance with EISA2007
  • IP55 enclosure on cast iron frames
  • Inverter Duty 10:1 Variable Torque and 2:1 Constant Torque
  • Class F Insulation 40C Max Ambient, 1.0SF on Inveter Power and 1.15SF on Sine Wave Power
  • Standard F1, reversible to F2 assembly. Dual frame mounting holes.
  • C-face addition may result in non-NEMA "BA" dim. For new "BA" dim consult chart found in modification section
  • Hazardous Duty Division 2, Zone 2, Class I, Groups A,B,C,D, Temperature code T2B
  • UL® Recognized & CSA certified and CE® Mark

Check Inventory


Key Features


  • Meets or exceeds NEMA Premium® efficiency. Model is in compliance with EISA2007
  • 100% cast iron construction for rigidity and reduced vibration
  • Meets IEEE45 USCG Marine Duty,Meets Ford EM1 Automotive Duty Specification
  • MAX GUARD® Class H insulation system
  • IP55 protection
  • Constant Torque for inverter duty
  • Sintered bronze breather with brass drain & breather
  • Bearing caps, Precision balanced to .08”/sec
  • 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power
  • Internal and external epoxy finish

Check Inventory


Key Features


  • 10:1 Variable torque, see Inverter Duty column for constant torque
  • MAX GUARD® Class F insulation system
  • Blue Chip® quality, 100% cast iron construction for rigidity and reduced vibration
  • Internal and external surfaces treated with epoxy paint
  • 1.15 Service Factor on sinewave or 1.0 Service Factor on IGBT power
  • Precision balanced to .08”/sec.
  • Extended grease tubes
  • Normally closed thermostats (must be connected to control circuit)
  • Meets temperature code T3B, Shaft slinger
  • Roller bearing on shaft end for belted load only

Check Inventory


Key Features


  • Meets or exceeds NEMA Premium® efficiencies
  • Inverter duty 10:1 variable torque and Constant torque, as noted
  • 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power
  • Motor will accept a C-face kit
  • Class H insulation
  • Roller bearing on shaft end for belted load only
  • 12 Leads for WYE-DELTA, part winding on low voltage, or across-the-line starting

Check Inventory


Key Features


  • Blue Chip® quality, 100% cast iron construction for rigidity and reduced vibration
  • Internal and external epoxy paint
  • IP55 enclosure
  • Rated 60/50 hertz, 190/380 or 380 volt at next lower horsepower
  • Extended grease tubes, regreasable in service
  • T-drains provided for effective drainage (Installed in both endshields
  • Suitable for shaft down mounting
  • Shaft Slinger
  • Forsheda seals on both ends
  • Actual test and vibration data supplied with each motor

Check Inventory


Key Features


  • Inverter-rated; Nameplated for 50 Hz operation
  • Class B insulation systems, Class F 140 frame and higher
  • Shielded ball bearings for direct coupled applications Contact your local sales office for belted load applications
  • Cast Iron
  • UL recognized and CSA certified

Check Inventory


Key Features


  • Complete cast iron construction for rigidity and reduced vibration
  • Epoxy painted; Severe duty treatment of internal parts
  • Class F insulation; Regreasable bearings
  • Inpro Shaft seal protected; Shaft grounding ring (SGRs) installed
  • Inverter rated IRIS™ insulation system
  • 10 : 1 constant and variable torque rated
  • 1.15 S.F. under sine wave power

Check Inventory


Key Features


  • Complete cast iron construction for rigidity and reduced vibration
  • Epoxy painted; Severe duty treatment of internal parts
  • Class F insulation; Regreasable bearings
  • Inpro Shaft seal protected; Shaft grounding ring (SGRs) installed
  • Inverter rated IRIS™ insulation system
  • 10 : 1 constant and variable torque rated
  • 1.15 S.F. under sine wave power

Check Inventory


Key Features


  • Complete cast iron construction for rigidity and reduced vibration
  • Epoxy painted; Severe duty treatment of internal parts
  • Class F insulation; Regreasable bearings
  • F-1 / F-2 capable; Brass T-drain installed - both ends at 6:00
  • Inpro shaft seal protected
  • Shaft grounding ring (SGRs) installed
  • Inverter rated IRIS® insulation system
  • 10:1 constant and variable torque rated
  • Designed for shaft up mounting
  • 1.15 S.F. under sine wave power

Check Inventory


Key Features


  • Meets UL and CSA safety requirements
  • Automatic overload protected
  • Explosion rated conduit box included
  • Internal mounted capacitors
  • Double shielded ball bearings
  • Meets temperature code T3B

Check Inventory


Key Features


  • Meets UL and CSA safety requirements
  • Automatic overload protected
  • Explosion rated conduit box included
  • Internal mounted capacitors
  • Double shielded ball bearings
  • Meets temperature code T3B

Check Inventory


Key Features


  • Inverter-rated; Nameplated for 50 Hz operation
  • Class B insulation systems, Class F 140 frame and higher
  • Shielded ball bearings for direct coupled applications Contact your local sales office for belted load applications
  • Rolled steel
  • UL recognized and CSA certified
  • Premium efficient ratings

Check Inventory


Key Features


  • Meets or exceeds NEMA® premium efficiencies
  • Class F insulation
  • Stamped steel conduit box
  • Standard assembly F1, reversible to F2 by reassembly
  • UL Recognized, CSA Certified, CE Mark
  • Provisions for Shaft Grounding Rings

Check Inventory


Key Features


  • Well-suited for Commercial and Large Residential Pools
  • Premium Efficient Designs
  • Special JMZ Shaft Configuration
  • 40°C Ambient
  • Double Shielded Ball Bearing
  • Rigid Base
  • 303 Stainless Steel Shaft Extension
  • Open Dripproof
  • Replaces Pentair Motor #357070S
  • Replaces Pentair Pump Model #EQK1000

Check Inventory


Key Features


  • USDA-approved epoxy painted motors
  • NEMA motors
  • AC washdown
  • Rigid base and C face mount types
  • BISSC approved designs; Double lip contact seals and v-ring seals used for shaft seals
  • Washdown brakemotors and pump motors available
  • UL recognized and CSA certified
  • Double lip contact seals and v-ring seals used for shaft seals

Check Inventory


Key Features


  • No features available

Check Inventory