7462 results for AC Motors - NEMA

AC Motors - NEMA

7221 - 7240 of 7462

Key Features


  • Meets or exceeds NEMA Premium® efficiencies NEMA Premium® models are in compliance with EISA2007
  • Motors are suitable for 10:1 VT on all frame sizes and 10:1 CT up to 365T frame (Except where noted)
  • 1.15 Service Factor
  • Normally closed thermostats, as noted
  • Class F Insulation
  • Nameplated 60/50 hertz
  • UL Recognized, CSA Certified and CE Marked

Key Features


  • Meets or exceeds all USA mandated efficiencies
  • Motors are suitable for 10:1 VT and 10:1 CT
  • 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power
  • 12 Leads for WYE-DELTA, part winding on low voltage, or across-the-line starting

Key Features


  • Meets or exceeds NEMA Premium® efficiencies, except where noted NEMA Premium® models are in compliance with EISA2007
  • Meets IEEE45 USCG Marine Duty, IP54 Construction, Meets Ford EM1 Automotive Duty Specification
  • Blue Chip® quality, 100% cast iron construction for rigidity and reduced vibration
  • Provisions to add stub shaft for an encoder (182T-449T, TEFC only)
  • Internal and external epoxy paint
  • MAX GUARD® Class F insulation system
  • Constant Torque speed range is listed in CT SPEED RANGE column
  • 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power
  • Bearing caps (254T and larger), Precision balanced to .08”/sec

Key Features


  • Ball bearings (except where noted)
  • NEMA Service Factors
  • Will accept C-Face Kits except where noted, see Accessories Section
  • UL Recognized and CSA Certified
  • See XRI® Dripproof in Premium Efficiency section for NEMA Premium efficiencies

Key Features


  • Ball bearings, mechanically locked on shaft end
  • NEMA Service Factors
  • Rated 60/50 hertz, 190/380 or 380 volt at next lower horsepower
  • 12 Leads for WYE-DELTA, part winding on low voltage, or across-the-line starting
Severe Duty Motor, 100 HP, 3 Ph, 60 Hz, 460 V, 1800 RPM, 405T Frame, TEFC

Severe Duty Motor, 100 HP, 3 Ph, 60 Hz, 460 V, 1800 RPM, 405T Frame, TEFC

Part #:405THFS19327
Catalog #:W600-P
Sorry, this item is no longer available

Key Features


  • Meets or exceeds NEMA Premium® efficiency. Model is in compliance with EISA2007
  • Meets IEEE-841 standard for severe duty applications
  • Bearing Current Protection (BCP)
  • Blue Chip® quality, 100% cast iron construction for rigidity and reduced vibration
  • Inpro/Seal® VBX® bearing isolators on drive end shaft extension TENV and on both ends of TEFC
  • Provisions to add stub shaft for an encoder (182T-449T, TEFC only)
  • Internal and external epoxy finish
  • MAX GUARD® Class F insulation system
  • Constant Torque speed range is listed in CT SPEED RANGE column

Key Features


  • Meets NEMA Premium® efficiencies, Bearing Current Protection (BCP), as noted
  • 10:1 Variable torque, see Inverter Duty column for constant torque
  • MAX GUARD® Class F insulation
  • Blue Chip® quality, 100% cast iron construction for rigidity and reduced vibration
  • Internal and external surfaces treated with epoxy paint
  • 1.15 Service Factor on sinewave or 1.0 Service Factor on IBGT power
  • Precision balanced to .08”/sec, Extended grease tubes
  • Normally closed thermostats (must be connected to control circuit)
  • Meets temperature code T3B, Shaft slinger, Nameplated 60/50 Hz, 190/380 Volts, at next lower HP, as noted
  • Ball Bearings (except as noted), Ball Bearings (except as noted)

Key Features


  • Meets or exceeds NEMA Premium® efficiency. Model is in compliance with EISA2007
  • 182T-365T models steel frame, 404T-449T models cast iron frame
  • Inverter Duty 20:1 Variable Torque
  • Class F Insulation
  • Standard F1, reversible to F2 assembly. Dual frame mounting holes.

Severe Duty Motor, 75 HP, 3 Ph, 60 Hz, 460 V, 444T Frame, TEFC

Part #:444THFCD9101
Catalog #:W597A
Sorry, this item is no longer available

Key Features


  • Meets IEEE-841 standard for severe duty motor applications; Meets General Motors® GM® 7E-TA automotive duty specification and Meets IEEE45 USCG marine duty, API RPI4F for offshore platforms
  • IP-56 cast iron, Meets or exceeds NEMA Premium® efficiencies, NEMA Premium models are in compliance with EISA2007; Actual test and vibration data supplied with each motor
  • MAX GUARD® Class F Insulation System, Inverter duty 10:1 variable torque and 10:1 constant torque & 1.15 service factor on Sine Wave Power 1.0 SF on Inverter Power
  • F1/F2 capable, Precision balanced to .08”/sec, Steel conduit box
  • Inpro/Seal® VBX® bearing isolators on drive end shaft extension TENV and on both ends of TEFC
  • NOTE: BCP (-P) models are not Hazardous Duty® motors certified for Division 2 locations, and Hazardous Duty® motors meet division 2 CSA certification when BCP is not employed, nameplate Division 2 / zone 2 class I (gases), groups A, B, C, D Meets temperature code T2B
  • 40°C Ambient 1.15SF Sine Wave Power and 1.0SF inverter power;
  • Provisions to add stub shaft for an encoder (182-449T, TEFC only, Modifications and Kits are available
  • UL® Recognized & CSA certified and CE® Mark

Key Features


  • Meets or exceeds NEMA Premium® efficiency. Model is in compliance with EISA2007
  • Motor will accept a C-face kit
  • Part winding start capability

Key Features


  • Mechanically locked on shaft end
  • Rated 60/50 hertz, 190/380 or 380 volt at next lower horsepower
  • 12 Leads for WYE-DELTA, part winding on low voltage, or across-the-line starting

Severe Duty Motor, 125 HP, 3 Ph, 60 Hz, 460 V, 3600 RPM, 444TS Frame, TEFC

Part #:444TSHFN19002
Catalog #:W604A
Sorry, this item is no longer available

Key Features


  • Meets or exceeds NEMA Premium® efficiency. Model is in compliance with EISA2007
  • Meets IEEE-841 standard for severe duty applications
  • Constant Torque speed range is listed in CT SPEED RANGE column
  • Blue Chip® quality, 100% cast iron construction for rigidity and reduced vibration
  • Inpro/Seal® VBX® bearing isolators on drive end shaft extension TENV and on both ends of TEFC
  • Provisions to add stub shaft for an encoder (182T-449T, TEFC only)
  • Internal and external epoxy finish
  • MAX GUARD® Class F insulation system

Key Features


  • Meets or exceeds NEMA Premium® efficiencies
  • Normal thrust
  • Class F insulation
  • Suitable for 230 volt part winding start through 100 HP (dual voltage motors)
  • Heavy duty lifting lugs
  • Drip cover/canopy cap included

Key Features


  • Normal and Medium thrust
  • EPAct and NEMA Premium efficiencies
  • Ball bearings and angular contact bearings for medium thrust applications
  • Class B insulation
  • 1.15 Service Factor
  • Suitable for 230 volt part winding start through 100 HP (dual voltage motors)
  • Heavy duty lifting lugs
  • Drip cover/canopy cap included
  • UL Recognized and CSA Certified
  • UL Listed for Fire Pump applications (except as noted)

Key Features


  • Normal and Medium thrust
  • EPAct and NEMA Premium efficiencies
  • Ball bearings and angular contact bearings for medium thrust applications
  • Class B insulation
  • 1.15 Service Factor
  • Suitable for 230 volt part winding start through 100 HP (dual voltage motors)
  • Heavy duty lifting lugs
  • Drip cover/canopy cap included
  • UL Recognized and CSA Certified
  • UL Listed for Fire Pump applications (except as noted)

Fire Pump Motor, 200 HP, 3 Ph, 60 Hz, 575 V, 3600 RPM, 444TS Frame, DP

Part #:444TSTDCD4008
Catalog #:U1127
Sorry, this item is no longer available

Key Features


  • Designed for use on pumps for fire pump duty
  • UL file EX5190, CSA file LR2025 and CE mark
  • 50°C ambient
  • Red paint on 25 HP through 200 HP
  • NEMA Design B, Code G or less
  • Will accept C-Face kits.
  • Single voltage motors have 12 leads and are suitable for wye-delta, across the line, or part winding start
  • Dual voltage motors have 12 leads, suitable for wye-delta or across the line start on either voltage, or part winding start on low voltage
  • Rated 60/50 hertz, 190/380 or 380 volt at next lower horsepower

Key Features


  • Red paint on 25 HP through 200 HP
  • NEMA Design B, Code G or less
  • Dual voltage motors have 12 leads, suitable for wye-delta or across the line start on either voltage, or part winding start on low voltage
  • Single voltage motors have 12 leads and are suitable for wye-delta, across the line, or part winding start
  • Will accept C-Face kits.
  • 230/460 and 460 Volt models rated for 50 HZ at next lower HP, 1.15 SF
  • Will become build-up item when current stock is gone

Key Features


  • Meets or exceeds NEMA Premium® efficiency. Model is in compliance with EISA2007
  • Meets IEEE-841 standard for severe duty applications
  • Constant Torque speed range is listed in CT SPEED RANGE column
  • Blue Chip® quality, 100% cast iron construction for rigidity and reduced vibration
  • Inpro/Seal® VBX® bearing isolators on drive end shaft extension TENV and on both ends of TEFC
  • Provisions to add stub shaft for an encoder (182T-449T, TEFC only)
  • Internal and external epoxy finish
  • MAX GUARD® Class F insulation system
  • Will become build-up item when current stock is gone

Key Features


  • Normal and Medium thrust
  • EPAct and NEMA Premium efficiencies
  • Ball bearings and angular contact bearings for medium thrust applications
  • Class B insulation
  • 1.15 Service Factor
  • Suitable for 230 volt part winding start through 100 HP (dual voltage motors)
  • Heavy duty lifting lugs
  • Drip cover/canopy cap included
  • UL Recognized and CSA Certified
  • UL Listed for Fire Pump applications (except as noted)

Key Features


  • Meets or exceeds NEMA Premium® efficiency. Model is in compliance with EISA2007
  • Motor will accept a C-face kit