7462 results for AC Motors - NEMA

AC Motors - NEMA

7381 - 7400 of 7462

Key Features


  • Meets or exceeds NEMA Premium® efficiency. Model is in compliance with EISA2007
  • Motor will accept a C-face kit
  • 12 Leads for WYE-DELTA, part winding on low voltage, or across-the-line starting

Key Features


  • Meets or exceeds NEMA Premium® efficiency. Model is in compliance with EISA2007
  • C-Face Footed models are rated 60/50 Hz, same HP
  • 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power
  • F1 conduit box on Rigid Base, F3 on C-Face Footed (Rigid Base) motors
  • Motor will accept a C-face kit
  • Shaft slinger, Class H insulation

Key Features


  • IP-22 Cast Iron, Meets or exceeds NEMA Premium® efficiencies, NEMA Premium models are in compliance with EISA2007
  • Class F Insulation System, Inverter duty 10:1 variable torque & 1.15 service factor on Sine Wave Power 1.0 SF on Inverter Power
  • F1/F2 capable, Dynamically balanced rotors, Steel conduit box
  • 40°C Ambient 1.15SF Sine Wave Power and 1.0SF inverter power
  • Start Method includes PWS or Inverter Start
  • Double-shielded ball bearings
  • Provisions Only for Drip Cover, Other Modifications and Kits are available
  • UL Recognized, CSA Certified, and CE Mark

Key Features


  • Meets or exceeds NEMA Premium® efficiency. Model is in compliance with EISA2007
  • Meets IEEE45 USCG Marine Duty, IP54 Construction, Meets Ford EM1 Automotive Duty Specification
  • Blue Chip® quality, 100% cast iron construction for rigidity and reduced vibration
  • Provisions to add stub shaft for an encoder (182T-449T, TEFC only)
  • Internal and external epoxy paint
  • MAX GUARD® Class F insulation system
  • Constant Torque speed range is listed in CT SPEED RANGE column
  • 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power
  • Bearing caps (254T and larger), Precision balanced to .08”/sec

Key Features


  • Red paint on 25 HP through 200 HP
  • NEMA Design B, Code G or less
  • Dual voltage motors have 12 leads, suitable for wye-delta or across the line start on either voltage, or part winding start on low voltage
  • Single voltage motors have 12 leads and are suitable for wye-delta, across the line, or part winding start
  • Will accept C-Face kits.
  • 230/460 and 460 Volt models rated for 50 HZ at next lower HP, 1.15 SF
  • Will become build-up item when current stock is gone

Key Features


  • Cast iron construction
  • Oversized, fully gasketed, cast iron conduit box
  • Oversized ball bearings
  • NEMA Design B
  • Class F insulation
  • V-Ring shaft seals

Key Features


  • Meets or exceeds NEMA Premium® efficiencies, except where noted NEMA Premium® models are in compliance with EISA2007
  • Suitable for use on a VFD. Variable Torque and Constant Torque (as noted)
  • 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power
  • F1 conduit box on Rigid Base, F3 on C-Face Footed (Rigid Base) motors
  • Bearing Current Protection (BCP), as noted
  • Shaft slinger, Class F insulation, 1.15 Service Factor, Ball bearings (except as noted)
  • C-Face Footed models are rated 60/50 Hz, same HP
  • Motors accept C-face kits, as noted
  • UL Recognized, CSA Certified and CE Mark

Key Features


  • Meets or exceeds NEMA Premium® efficiencies, except where noted NEMA Premium® models are in compliance with EISA2007
  • Suitable for use on a VFD. Variable Torque and Constant Torque (as noted)
  • 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power
  • F1 conduit box on Rigid Base, F3 on C-Face Footed (Rigid Base) motors
  • Bearing Current Protection (BCP), as noted
  • Shaft slinger, Class F insulation, 1.15 Service Factor, Ball bearings (except as noted
  • C-Face Footed models are rated 60/50 Hz, same HP
  • Motors accept C-face kits, as noted
  • UL Recognized, CSA Certified and CE Mark

Key Features


  • Meets or exceeds NEMA Premium® efficiency. Model is in compliance with EISA2007
  • Meets IEEE45 USCG Marine Duty, IP54 Construction, Meets Ford EM1 Automotive Duty Specification
  • Blue Chip® quality, 100% cast iron construction for rigidity and reduced vibration
  • Provisions to add stub shaft for an encoder (182T-449T, TEFC only)
  • Internal and external epoxy paint
  • MAX GUARD® Class H insulation system
  • Constant Torque speed range is listed in CT SPEED RANGE column
  • 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power
  • Bearing caps (254T and larger), Precision balanced to .08”/sec

Key Features


  • Meets or exceeds NEMA Premium® efficiencies, except where noted NEMA Premium® models are in compliance with EISA2007
  • Meets IEEE45 USCG Marine Duty, IP54 Construction, Meets Ford EM1 Automotive Duty Specification
  • Blue Chip® quality, 100% cast iron construction for rigidity and reduced vibration
  • Provisions to add stub shaft for an encoder (182T-449T, TEFC only)
  • Internal and external epoxy paint
  • MAX GUARD® Class F insulation system
  • Constant Torque speed range is listed in CT SPEED RANGE column
  • 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power
  • Bearing caps (254T and larger), Precision balanced to .08”/sec

Key Features


  • Blue Chip® quality, 100% cast iron construction for rigidity and reduced vibration
  • Internal and external epoxy paint
  • Class F insulation, 1.15 Service Factor
  • Rated 60/50 hertz, 190/380 or 380 volt at next lower horsepower
  • Extended grease tubes, Regreasable in service
  • T-drains provided for effective drainage (Installed in both endshields
  • Suitable for shaft down mounting
  • Shaft Slinger, Ball Bearings
  • Forsheda seals on both ends
  • Actual test and vibration data supplied with each motor, UL Recognized and CSA Certified,

Key Features


  • Frame constructions are heavy gauge steel or Aluminum, as noted
  • 1.15 Service Factor
  • Nameplated 60/50 hertz at next lowest horsepower
  • Will accept C-Face Kits as noted.
  • Severe duty kits available.
  • Shaft slinger, regreasable bearings (182T and larger), lead lugs (364T and larger), and bearing caps on 444T and larger
  • Ball Bearings, except where noted
  • UL Recognized and CSA Certified

Key Features


  • Meets or exceeds NEMA Premium® efficiency. Model is in compliance with EISA2091
  • Meets IEEE-841 standard for severe duty applications
  • 100% cast iron construction for rigidity and reduced vibration
  • Inpro/Seal® VBX® bearing isolators on drive end shaft extension TENV and on both ends of TEFC
  • IP56 protection
  • MAX GUARD® Class H insulation system
  • Constant torque for inverter duty
  • Sintered bronze breather with brass drain & breather
  • Bearing caps, Precision balanced to .08”/sec
  • 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power

Key Features


  • Meets or exceeds NEMA Premium® efficiency. Model is in compliance with EISA2007
  • Motor will not accept a C-face kit
Encoder Motor, 200 HP, 3 Ph, 60 Hz, 460 V, 1800 RPM, 445T Frame, TEFC

Encoder Motor, 200 HP, 3 Ph, 60 Hz, 460 V, 1800 RPM, 445T Frame, TEFC

Part #:445THFN8040
Catalog #:Y578
Sorry, this item is no longer available

Key Features


  • MAX GUARD® Class H insulation system
  • Constant torque operation from 0 to base speed on vector drive, including TEFC (On Volts/Hertz drives, TEFC motors are limited to 20:1 constant torque
  • Constant HP operation to twice base speed (143-256 frame);1.5 times base (all others)
  • Optimized for operation with IGBT inverter (NEMA Design A)
  • Normally closed thermostats (one per phase, class F)
  • Blue Chip quality, cast iron frame and brackets
  • Patented “fracket” design (TEBC enclosure)

Key Features


  • Meets or exceeds NEMA Premium® efficiencies, except where noted NEMA Premium® models are in compliance with EISA2007
  • C-Face Footed models are rated 60/50 Hz, same HP
  • 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power
  • F1 conduit box on Rigid Base, F3 on C-Face Footed (Rigid Base) motors
  • Motor will accept a C-face kit
  • Shaft slinger, Class F insulation, 1.15 Service Factor, Ball bearings (except as noted
  • Part winding start capability

Key Features


  • Meets or exceeds NEMA Premium® efficiency. Model is in compliance with EISA2007
  • Roller bearing on shaft end for belted load only
  • 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power
  • F1 conduit box on Rigid Base, F3 on C-Face Footed (Rigid Base) motors
  • Motor will accpet a C-face kit
  • Shaft slinger, Class F insulation
  • C-Face Footed models are rated 60/50 Hz, same HP

Key Features


  • Meets or exceeds NEMA Premium® efficiency. Model is in compliance with EISA2007
  • Suitable for use on a VFD. Variable Torque and Constant Torque (as noted)
  • 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power
  • F1 conduit box on Rigid Base, F3 on C-Face Footed (Rigid Base) motors
  • Bearing Current Protection (BCP), as noted
  • Shaft slinger, Class F insulation
  • C-Face Footed models are rated 60/50 Hz, same HP
  • Motors accept C-face kits, as noted

Key Features


  • Meets or exceeds NEMA Premium® efficiency. Model is in compliance with EISA2007
  • Motor will accept a C-face kit
  • Rated 60/50 hertz, 190/380 or 380 volt at next lower horsepower
  • 12 Leads for WYE-DELTA, part winding on low voltage, or across-the-line starting

Key Features


  • Red paint on 25 HP through 200 HP
  • NEMA Design B, Code G or less
  • Dual voltage motors have 12 leads, suitable for wye-delta or across the line start on either voltage, or part winding start on low voltage
  • Single voltage motors have 12 leads and are suitable for wye-delta, across the line, or part winding start
  • Will accept C-Face kits.
  • 230/460 and 460 Volt models rated for 50 HZ at next lower HP, 1.15 SF
  • Will become build-up item when current stock is gone